Post Frame Construction
Roof
The thermal values for roof applications in post frame construction were derived by testing an assembly consisting of a corrugated metal exterior, 2" x 4" purlins, TempShield™ Insulation, a 2" x 6" to represent the top cord of a truss, and 1/2" wafer board. The thermal values are for both exposed insulation and applications where the insulation is covered for fire codes.
| Thermal Values | Heat Flow Up |
Heat Flow Down |
U Value Up |
U Value Down |
K Value Up |
K Value Down |
|---|---|---|---|---|---|---|
| TempShield™ w/Wafer Board |
6.93 | 15.11 | .144 | .066 | .144 | .066 |
| TempShield™ w/Metal Interior |
6.22 | 14.40 | .161 | .069 | .161 | .069 |
| TempShield™ Exposed to Interior |
4.91* | 12.81* | .204* | .078* | .204* | .078* |
All Thermal Values are corrected for frame loss.
* Includes thermal resistance of 1.32 UP and 4.55 DOWN for interior air film.
Walls
The thermal values for TempShield™ installed in the walls of post frame buildings are based on testing of an assembly consisting of corrugated metal exterior, 2" x 4" girts, TempShield™ Insulation, a 4" x 6" to represent the support beam, and 1/2" wafer board as an interior wall covering.
| Thermal Values | Heat Flow Horz. | U Value Horiz. | K Value Horiz. |
|---|---|---|---|
| TempShield™ w/Wafer Board | 6.93 | .144 | .144 |
| TempShield™ w/Metal Interior | 6.22 | .161 | .161 |
| TempShield™ Exposed to Interior | 4.91* | .204* | .204* |
All Thermal Values are corrected for frame loss.
* Includes thermal resistance of 1.70 for interior air film.