Post Frame Construction
Roof
The thermal values for roof applications in post frame
construction were derived by testing an assembly consisting of
a corrugated metal exterior, 2" x 4" purlins, TempShield™
Insulation, a 2" x 6" to represent the top cord of a truss,
and 1/2" wafer board. The thermal values are for both
exposed insulation and applications where the insulation is
covered for fire codes.
| Thermal Values |
Heat Flow Up |
Heat Flow Down |
U Value Up |
U Value Down |
K Value Up |
K Value Down |
TempShield™ w/Wafer Board |
6.93 |
15.11 |
.144 |
.066 |
.144 |
.066 |
TempShield™ w/Metal Interior |
6.22 |
14.40 |
.161 |
.069 |
.161 |
.069 |
| TempShield™ Exposed to Interior |
4.91* |
12.81* |
.204* |
.078* |
.204* |
.078* |
All Thermal Values are corrected for frame loss.
* Includes thermal resistance of
1.32 UP and 4.55 DOWN for interior air film.
Walls
The thermal values for TempShield™ installed in the walls of post frame buildings are based on
testing of an assembly consisting of corrugated metal
exterior, 2" x 4" girts, TempShield™ Insulation, a 4" x 6" to represent the support beam, and
1/2" wafer board as an interior wall covering.
| Thermal Values |
Heat Flow Horz. |
U Value Horiz. |
K Value Horiz. |
| TempShield™ w/Wafer Board |
6.93 |
.144 |
.144 |
| TempShield™ w/Metal Interior |
6.22 |
.161 |
.161 |
| TempShield™ Exposed to Interior |
4.91* |
.204* |
.204* |
All Thermal Values are corrected for frame loss.
* Includes thermal resistance of
1.70 for interior air film.
|